This Sugam Toilet product comes in 4 sizes:
1) Sugam - III
2) Sugam - IV
3) Sugam - II
4) Sugam - 347
Detailed Specifications:
1) SPECIFICATION OF SUPERSTRUCTURE KIT FOR PREFABRICATED TOILET BLOCK “SUGAM-3” Code No. 33-33-70
Description :
SINTEX prefabricated toilet shall be suitable for mounting Ready-made plinth. The components shall be fabricated at factory for easy to assembly at site.
Size :
‘0.84 mt.x 0.80 mt. x 1.8 / 1.7 mt. - as per enclosed drawing.
Wall :
The walls shall be made of Sandwich panels. The sandwich panels shall be made out of 0.30 mm thick Pre coated steel sheet on both side of PUF (Polyurethane foam). The total thickness of panel not less than 20mm. The colour of both skin sheet of wall shall be white.
Joinery of Wall Panels :
The walls shall be fixed with MS Bottom ‘U’ track & MS Vertical corner columns. The bottom ‘U’ track shall be fixed with plinth by using necessary Nail / Screws. The ‘U’ track and columns shall be made out with powder coated, 0.8 mm thick press steel sheet.
Roof :
The Roof cladding shall be done with 0.5 mm thick PPGI Profile sheets. These sheets are laid over a wall top and fixed using suitable fasteners. External colour of roof sheet is Tera-cota.
Door :
The door frame shall be made out of Powder coated 0.8 mm thick press steel sheet in require size and shape. The door shutter shall be made out with 20 mm thick PUF insulated sandwich panel, as per wall panel. The door shutter shall be fixed with the door frame with 3 nos. hinges. The door shutter shall be provided with 1 No. aldrops at outside, 1 no. Tower bolts at the center inside and handles shall be provided on both the sides. The size of door shall be as per mention in enclosed drawing.
Ventilation :
Sufficient open gap shall be provided at three sides of toilet in between Roof sheet & wall / door for air ventilation as per shown in the enclosed drawing.
Note : Any kind of Civil work, Foundation, plinth, flooring, WC pan, P trap, Pipe line work, Electrification work are not in Sintex’s scope of work.
2) SPECIFICATION OF SUPERSTRUCTURE KIT FOR PREFABRICATED TOILET BLOCK “SUGAM-4” Code No. 33-39-70
Description :
-------- Same as for “SUGAM-3” above ----------
Size :
‘0.84 mt.x 0.95 mt. x 1.8 / 1.7 mt. - as per enclosed drawing.
Wall :
-------- Same as for “SUGAM-3” above ----------
Joinery of Wall Panels :
-------- Same as for “SUGAM-3” above ----------
Roof :
-------- Same as for “SUGAM-3” above ----------
Door :
-------- Same as for “SUGAM-3” above ----------
Ventilation :
-------- Same as for “SUGAM-3” above ----------
Note : Any kind of Civil work, Foundation, plinth, flooring, WC pan, P trap, Pipe line work, Electrification work are not in Sintex’s scope of work.
3) SPECIFICATION OF SUPERSTRUCTURE KIT FOR PREFABRICATED TOILET BLOCK “SUGAM-2” Code No. 39-39-74
Description :
-------- Same as for “SUGAM-3” above ----------
Size :
‘1.0 mt.x 0.955 mt. x 2.1 / 2.05 mt. - as per enclosed drawing.
Wall :
-------- Same as for “SUGAM-3” above ----------
Joinery of Wall Panels :
The walls shall be fixed with MS Bottom frame & MS Vertical corner columns. The bottom frame shall be fixed with plinth by using necessary Nail / Screws. The Frame and columns shall be made out with powder coated, 1 mm thick press steel sheet.
Roof :
-------- Same as for “SUGAM-3” above ----------
Door :
The door frame shall be made out of Powder coated 1 mm thick press steel sheet in require size and shape. The door shutter shall be made out with 20 mm thick PUF insulated sandwich panel, as per wall panel. The door shutter shall be fixed with the door frame with 3 nos. hinges. The door shutter shall be provided with 1 No. aldrops at outside, 1 no. Tower bolts at the center inside and handles shall be provided on both the sides. The size of door shall be as per mention in enclosed drawing.
Ventilation :
-------- Same as for “SUGAM-3” above ----------
Note : Any kind of Civil work, Foundation, plinth, flooring, WC pan, P trap, Pipe line work, Electrification work are not in Sintex’s scope of work.
4) SPECIFICATION OF SUPERSTRUCTURE KIT FOR PREFABRICATED TOILET BLOCK “SUGAM-347” Code No. 36-48-82
Description :
-------- Same as for “SUGAM-3” above ----------
Size :
‘0.958 mt.x 1.22 mt. x 2.1 / 2.0 mt. - as per enclosed drawing.
Wall :
-------- Same as for “SUGAM-3” above ----------
Joinery of Wall Panels :
-------- Same as for “SUGAM-2” above ----------
Roof :
-------- Same as for “SUGAM-3” above ----------
Door :
-------- Same as for “SUGAM-2” above ----------
Ventilation :
-------- Same as for “SUGAM-3” above ----------
Note : Any kind of Civil work, Foundation, plinth, flooring, WC pan, P trap, Pipe line work, Electrification work are not in Sintex’s scope of work.
Sugam Toilet
Please see Technical Specifications in Main Description